QEW7 Solar Cell Spectral Response / QE / IPCE Measurement System

QEW7 Solar Cell Spectral Response Measurement System/QE/IPCE

A tungsten filament light source, monochromator, filters, and reflective optics provide monochromatic light to a photovoltaic device while a broadband bias light illuminates the test device to simulate end-use conditions. The monochromator, filter wheel, and digital signal processing equipment are controlled by a computer, which also interprets signals, maintains calibration information, saves test data, and produces test reports. This system can measure a wide variety of photovoltaic devices, including p-n junction and dye-nanocrystalline solar cells.

Basic System Features

  • Dual grating monochromator with computer control
  • Filter wheel with order-sorting and stray light attenuation filters
  • Calibrated reference photodiode
  • Line filter for wavelength calibration verification
  • Simultaneous measurement of device response and light intensity
  • Computer system with easy-to-use graphical user interface
  • Monochromatic light spectral bandwidth approximately 5 nm (user-changeable) ‏ 360-1100 nm wavelength range
  • Selectable wavelength interval (default 5 nm)
  • Calculates Jsc estimate using reference spectrum
  • Voltage bias capability
  • White bias light source
  • Chopping speed 4-200 Hz
  • Measures silicon solar cell in 4-10 minutes Instruction manual
  • Customer training in Colorado

Options

  • Setup and training at customer's site
  • Test fixture and contacting mechanism for your devices
  • Temperature control for the optional test fixture
  • Multi-junction cell measurement capability
  • Other options are available; please contact us to discuss your requirements